在线看91 I 亚洲精品图片区小说区 I 碰碰av I 午夜精品一区二区在线观看 I 9i精品福利一区二区三区 I 亚洲欧洲一区二区 I 两根大肉大捧一进一出好爽视频 I 国产一区二区在线免费视频 I 天堂а√中文最新版地址在线 I 女同性一区二区三区人了人一 I 色综合天天综合天天更新 I 在线国产欧美 I 偷拍区另类综合在线 I 麻豆安全免费网址入口 I 免费高清在线观看免费 I 国产voyeur精品偷窥222 I 精品少妇嗷嗷叫在线观看视频 I 国产精品996 I 免费一区二区无码东京热 I 亚洲一级特黄毛片 I 免费看一级黄色毛片 I 午夜无码片在线观看影视 I 粉嫩少妇内射浓精videos I 三级黄色大片网站 I 欧美夜夜 I 久久久天堂 I 亚洲欧洲日产国码无码网站 I 亚洲狠狠干 I 哺乳一区二区久久久免费 I 久久伊人久久 I 久久精品国产亚洲aⅴ瑜伽 I 婷婷六月五月 I 9i看片成人免费高清 I 美女写真福利视频 I 男男做性免费视频网

郵箱:mkdzyhs@163.com 電話:18136969561

行業(yè)新聞


電路板的集成度有所提高

作者:shan 來源:本站 點(diǎn)擊:0 時(shí)間:2024-04-10 10:13:33

The damage to higher integration circuit boards nowadays can cause many unnecessary troubles, and the significance of circuit protection has many aspects. Preventing circuit damage is one of the more important aspects. For example, the usage environment of many car mounted devices is more harsh than that of general electronic products, and they will generate a large instantaneous peak voltage when starting and stopping. At this time, it is necessary to use overvoltage protection components in the power adapter of these electronic devices.

For example, communication equipment is often troubled by surges, which include surge voltage and surge current. They are a type of spike pulse with extremely fast rising speed and short duration, which can instantly exceed the peak value of the device's stable value. This requires the use of a combination of multiple voltage transient and surge protection devices to form a multi-level protection circuit to ensure foolproof operation.

Of course, in addition to preventing accidental circuit damage, it can be seen that the working voltage of semiconductor device ICs is developing towards lower and lower trends. Protecting their circuits can also reduce energy loss, reduce circuit heating, and extend the service life of ICs.

The development of integrated circuits has driven the increasing diversification and complexity of electronic circuit products, resulting in more situations that may harm circuits. Circuit protection has become increasingly important.

Devices required for different circuit protection

Overvoltage protection is already an essential part of the circuit. Overvoltage protection devices are responsible for protecting the circuit from high voltage. The principle of this device is to use the potential difference to achieve the effect of circuit protection. When the voltage in the circuit exceeds the specified value, the internal circuit structure of the overvoltage protection device generates a certain potential difference with the circuit, thereby enabling the circuit to achieve protection through impedance changes.

At the same time, the internal current and voltage protection device of the overvoltage protection device will disconnect the circuit, preventing the current from further flowing to the protected electrical appliance or equipment, achieving the effect of protecting the electrical appliance or equipment.

Typical overvoltage protection devices are varistors and transient suppressors (TVS). Varistors can be said to be the most commonly used overvoltage protection device, with low cost, good effect, and high cost-effectiveness. The ns level response speed enables it to handle overvoltage protection work in the vast majority of cases.

Based on the nonlinear volt ampere characteristics of varistors, under normal circumstances, varistors act as a switch in an open state. When an overvoltage exceeds their rated voltage in a circuit, the resistance value of the varistor rapidly decreases to reduce the impact of overvoltage on subsequent circuits.

The characteristic of TVS is its fast response. When the transient voltage is too high, the TVS diode produces avalanche, causing the instantaneous large current to be diverted from the low resistance path, avoiding circuit damage as a result. Both have their own focuses, and TVS has more advantages in dealing with transient overvoltage impacts.

Overcurrent devices often use various fuses, such as glass tube fuses, chip fuses, and polymer fuses. They are simple to use and have obvious effects. Polymer fuses limit current by increasing resistance and have excellent recoverable characteristics. When used for overcurrent protection, the circuit can automatically return to a conductive state.

Glass tube fuses and chip fuses are directly fusing conductive fuses. Nowadays, there are more and more solutions using eFusion, which directly tracks current and has its unique advantages.

In circuit protection, there are also some electrostatic protection components involved, especially in high integration circuits where ESD protection is not installed. The high-voltage ESD impact generated through interface connections can cause high current peaks to directly flow into the integrated circuit, causing damage. To protect sensitive circuits from electrical overstress faults, the ESD protection diode should be connected to each signal line between the interface connector and the integrated circuit, with different interface speeds corresponding to different capacitance values of the ESD diode.